          ModuTEMP® 70 Modular Resistance and Thermocouple Temperature Sensors       
              
    Measuring resistor 1x / 2x Pt100,
 thermocouple 1x / 2x “J“, “K“, “N“
Measuring range -200 to +700 °C (Pt100),
 -200 to +800 °C (“J“),
 -200 to +1300 °C (“K“, “N“)
Accuracy class A, B according to EN 60751,
 1, 2 according to EN 60584-1
Stem material stainless steel 1.4541, 1.4401, 2.4816, Nicrobell/Pyrosil
Extension piece (thermowell) materialstainless steel 1.4541
Protective tube material stainless steel 1.4541, 1.4845, 1.4762,
 Kanthal AF
Optional headmounted transmitter with output 4 to 20 mA, HART, Profibus, Fieldbus, including version with galvanic isolation and intrinsically safe versionHousing IP 65, IP 68Intrinsically safe version(Ex) II 1/2G Ex ia IIC T6…Tx°C Ga/Gb
 (Ex) II 1/2D Ex ia IIIC T200 85°C…T200 x°C Da/Db.
Flameproof enclosure (Ex) II 1/2G Ex db IIC T6...Tx°C Ga/Gb.
Protection by enclosure (Ex) II 1/2D Ex ta/tb IIIC T90°C…Tx°C Da/Db.
      Links and documentation: |  |